Table 1 Showing Raman dataset dimensions, acquisition times, and processing times.

From: Automated processing of label-free Raman microscope images of macrophage cells with standardized regression for high-throughput analysis

     

Z-LSR

SVD

Dataset

Dimensions

Acq. Time

Z-Score

Regr.

Total

 

SET1

120 × 400 × 1340

600 s

10 s

10 s

20 s

3.0 h

SET2

81 × 400 × 1340

405 s

5 s

7 s

12 s

1.5 h

SET3

206 × 400 × 1340

1030 s

18 s

15 s

33 s

6.5 h

  1. Processing times include automated cosmic ray removal (see methods sections) for all data sets. Set 1 can be projected to a 120 × 400 image of 2 macrophage cells. Set 2 corresponds to an 81 × 400 pixel image of 2 macrophage cells. Set 3 is a 206 × 400 pixel image of 8 macrophage cells. Times are actual running times on a 2.26 GHZ Quad-Core Intel Xeon 32GB DDR3 Mac Pro